Close
All Categories
    Filters
    Preferences
    Search

    Potter PAD300-PHD

    Photo Smoke/Heat Detector
    Availability: 5 in stock
    Manufacturer: Potter
    SKU: POT PAD300-PHD

    The PAD300-PHD from Potter is a Analog Addressable smoke detector and a rate of rise and/or fixed temperature heat detector compatible with fire alarm control panels that utilize the Potter Addressable Device (PAD) protocol. The PAD300-PHD is a low profile smoke/heat sensor with a wide sensitivity range. The heat sensing portion utilizes a proven thermistor for accurate and reliable heat detection. The PAD300-PHD is UL listed and has a sensitivity range of 1.1 to 3.5% per foot with a fix temperature alarm threshold of 135°F.

    Features

    • Heat Detector compliant with UL 521
    • Selectable Rate of Rise and/or Fixed Heat Detector
    • Reliable detection technology
    • Wide selectable smoke sensitivity range of 1.1 to 3.5%/foot
    • Detector communicates sensitivity to control panel
    • UL listed smoke calibration and sensitivity
    • Ambient temperature listing of 32 ° F to 115 ° F
    • Optional locking tab to prevent unwanted removal
    • Simple DIP switch address setting, no programming tool required
    • LED alarm indicator
    • Magnetic test switch

     

     

    The PAD300-PHD from Potter is a Analog Addressable smoke detector and a rate of rise and/or fixed temperature heat detector compatible with fire alarm control panels that utilize the Potter Addressable Device (PAD) protocol. The PAD300-PHD is a low profile smoke/heat sensor with a wide sensitivity range. The heat sensing portion utilizes a proven thermistor for accurate and reliable heat detection. The PAD300-PHD is UL listed and has a sensitivity range of 1.1 to 3.5% per foot with a fix temperature alarm threshold of 135°F.

    Features

    • Heat Detector compliant with UL 521
    • Selectable Rate of Rise and/or Fixed Heat Detector
    • Reliable detection technology
    • Wide selectable smoke sensitivity range of 1.1 to 3.5%/foot
    • Detector communicates sensitivity to control panel
    • UL listed smoke calibration and sensitivity
    • Ambient temperature listing of 32 ° F to 115 ° F
    • Optional locking tab to prevent unwanted removal
    • Simple DIP switch address setting, no programming tool required
    • LED alarm indicator
    • Magnetic test switch

     

     

    Products specifications
    Unit of Measure EACH
    Category Fire Alarm-Addressable Devices